Textured carport ceiling removed before new lights go in under an apartment building
Example project
- Home
- 1960s two-story apartment building in Hawthorne with a ground-floor carport under the upper units
- Original request
- Patch the carport ceiling and hang new light fixtures
- Testing
- A Cal/OSHA-certified asbestos consultant samples the sprayed texture at three points along the carport
- Found
- Asbestos in the texture at all three points
- Area
- About 215 sq ft of carport ceiling
- Timeline
- Notice no later than 10 working days ahead, then two working days
- Cost
- $2,800
Scope of work
Plastic hung around the work area with air filters running, the texture wetted and scraped into bags, a HEPA clean and the haul. The survey, the district notification fee, the clearance air test, the patching and the new lights are separate.
Project overview
In this example, the owner of a 1960s apartment building in Hawthorne wants new lights under the carport. The old ceiling has a sprayed texture where the fixtures will mount.
The samples all test positive. Because an apartment building is never a single-unit dwelling, the survey comes first and the abatement contractor files the district notice online. The abatement crew scrapes the texture before the electrician arrives.
The goal
The goal is a bare carport ceiling, so the new fixtures mount to a surface with nothing positive left on it.
Process
- First visit A Cal/OSHA-certified asbestos consultant samples the texture at three points.
- Before work The abatement contractor files the district notice online.
- Days one and two The work area is walled off with plastic and the texture is wetted and scraped.
- Last An independent consultant tests the air, then the electrician mounts the lights.
Planning right
- Tell residents which parking spaces are closed.
- Ask the consultant to mark each sample spot on a sketch of the carport.
- Book the electrician after the air results.
- Keep the lab report in the building file.